Time:2023.02.10Browse:
The centrifugal pump gas erosion is one of the common faults for centrifugal pumps. To solve the cause of centrifugal pump air erosion, you must first know the reasons for centrifugal pump air erosion. The main reason for centrifugal pump gas erosion is caused by the low liquid level. The solution to the centrifugal pump gas erosion is to increase the liquid level of the centrifugal pump to eliminate the failure. The following is a brief explanation of the parts and response measures that are prone to air erosion in the centrifugal pump. It is hoped that it will help the user's failure when using the centrifugal pump.
Corresponding pump is prone to air erosion parts
1. The lax cover with a large rotation rate and the low -voltage side near the edge of the inlet of the leaves.
2. Press the tongue of the tongue in the room and the low -voltage side of the imported edge.
3. There is no sealing gap between the leaf tip of the high -ratio of the front cover of the front cover and the low -pressure side of the leaf tip of the leaf tip.
4. Multi -level centrifugal pumps in the front level of the first level