Measures to prevent self -absorbing cardiac pump air intake

Time:2023.03.07Browse:

Share:


  1. The installation location of the self -suction pump should be as close as the water surface as much as possible to ensure that the air is not sucked into the air when the water level decreases.

  2. When installing the water absorption pipe road, the water intake pipe should always be tilted or installed horizontally. Any point of the water inlet pipe should not be higher than the pump into the water inlet, otherwise the air in the tube will be eliminated.

  3. To prevent the filler from giving up the air leakage. The loosening of the filler should be appropriate. If it is too loose, the filling cover should be tightly filled; the fillers are damaged and failed, and the water seal pipes at the coverage of the filler are blocked and fevered. Essence

  4. Before installing the water pipe connected to the French disk, you should clean up the planes of the two flanges in contact with each other, and add a 3 ~ 5mm thick glue pad in the middle. To gradually tighten the bolt in a few times.

  5. The bottom valve of the self -absorbing pump must have sufficient flooding depth. The depth of submerging from the valve plane should be equal to 1.5 to 2 times the outer diameter of the bottom valve, at least not less than 0.5m. If it is too shallow, it is easy to form vortex, which sucks the air, generates vapor erosion and damages the impeller and pump shell. If you find that the water pump is running quickly, you can put a few wooden boards on the water surface to reduce the vortex and prevent the air from entering the pump shell.

  6. The self -suction pump is equipped with a deflated screw. In order to facilitate the air deflation, you can use the same threaded faucet to replace the air -deformed screws. Open the faucet when you air deflation.

  7. The vacuum of the self -absorbing pump is limited. The vacuum is too large, which can easily vaporize the water in the pump and be unfavorable to the self -absorbing pump. Therefore, their respective water pumps have their maximum allowable suction, and they are generally between 3 and 8.5m, and they should be controlled in this range during installation.

  8. Pay attention to exhaust. Before starting the self -absorbing pump, the water should be added to eliminate the air in the self -absorbing pump; usually open the airwalk plug on the pump cover regularly to eliminate the air accumulated in it.


LAST: How to check whether the self -suction pump import pipe is leaked? NEXT:What are the disadvantages of self -suction pump for a long time?
Return

Recommended News